Agen Resmi Teledyne LeCroy Indonesia
WaveMaster 8 Zi-A Oscilloscopes
World's Highest Bandwidth Real-time Oscilloscope with Superior Performance
WaveMaster 8 Zi-A combines the highest bandwidth (45 GHz) and sample
rate (120 GS/s) with superior signal fidelity performance and 20 GHz on
all four input channels. Models are available from 4 to 45 GHz with
complete bandwidth upgradability throughout the range. The X-Stream II
architecture maximizes speed in all aspects and provides for full
analysis on maximum record lengths using LeCroy's flexible and deep
analysis toolbox. Explore WaveMaster 8 Zi-A
WaveMaster 804Zi-A (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 806Zi-A (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 808Zi-A (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 813Zi-A (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 816Zi-A (16 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 820Zi-A (20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 825Zi-A (25 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 830Zi-A (30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 845Zi-A (45
GHz Bandwidth, 1 Input Channel, 120 GS/s Max Sample Rate; 30 GHz
Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4
Input Channels, 40 GS/s Max Sample Rate)
Check up to three models.
Quick Specs
45 GHz Real-Time Bandwidth
LeCroy has again broken bandwidth barriers by utilizing widely
adopted and proven SiGe processes, custom 2nd generation ASIC designs,
and 6th generation Digital Bandwidth Interleave (DBI) technology to
achieve unprecedented real-time oscilloscope performance:- 45 GHz
- 120 GS/s
- 768 Mpts/Ch Analysis Memory
20 GHz/4ch Model
Four channel performance at 20 GHz is pristine with exceptional rise
time, overshoot, total and random jitter noise floor, and electrical
noise performance.
LeCroy — The Analysis Memory Leader
LeCroy has found a way to make long acquisition memory seamless and
pain free to use. The WaveMaster 8 Zi-A Series' proprietary X-Stream II
architecture supports capturing, zooming, measuring and analyzing
multiple waveforms at up to 768 Mpts deep. WaveMaster 8 Zi-A's
proprietary architecture design is augmented with an Intel® Core™ 2 Quad
processor (12 GHz effective clock rate), high-speed serial data buses,
Windows 7 64-bit OS and 8 GB of RAM. What you experience is processing
speed 10-100x faster compared to other oscilloscopes in this class.
Highest Stability Timebase and Lowest Jitter Noise Floor
An exceptionally accurate and stable time base is incorporated for
the best possible jitter measurement accuracy jitter noise floor is as
low as 125 fsrms. LeCroy provides highly stable measurements at full
(768 Mpts) record lengths, simplifying debug of low frequency events.
Freedom from Probing Limitations
High bandwidth differential probes (up to 25 GHz), single-ended
active probes, current probes, high-voltage, and mixed signals all
connect to the WaveMaster 8 Zi-A oscilloscope and give you a total
system view. All WaveMaster 8 Zi-A oscilloscopes contain selectable 50
Ohm and 1 MOhm input capability and can be used with any LeCroy probe -
passive or active - without requiring external adapters or power
supplies.