WaveMaster 8 Zi-A Oscilloscopes - Teledyne LeCroy Indonesia

Written By Anonymous on Selasa, 15 Januari 2013 | 14.12

Agen Resmi Teledyne LeCroy Indonesia

WaveMaster 8 Zi-A Oscilloscopes


World's Highest Bandwidth Real-time Oscilloscope with Superior Performance
WaveMaster 8 Zi-A combines the highest bandwidth (45 GHz) and sample rate (120 GS/s) with superior signal fidelity performance and 20 GHz on all four input channels. Models are available from 4 to 45 GHz with complete bandwidth upgradability throughout the range. The X-Stream II architecture maximizes speed in all aspects and provides for full analysis on maximum record lengths using LeCroy's flexible and deep analysis toolbox. Explore WaveMaster 8 Zi-A 

WaveMaster 804Zi-A  (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 806Zi-A  (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 808Zi-A  (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 813Zi-A  (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 816Zi-A  (16 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 820Zi-A  (20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 825Zi-A  (25 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 830Zi-A  (30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 845Zi-A  (45 GHz Bandwidth, 1 Input Channel, 120 GS/s Max Sample Rate; 30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
Check up to three models.
45 GHz Real-Time Bandwidth
LeCroy has again broken bandwidth barriers by utilizing widely adopted and proven SiGe processes, custom 2nd generation ASIC designs, and 6th generation Digital Bandwidth Interleave (DBI) technology to achieve unprecedented real-time oscilloscope performance:
  • 45 GHz
  • 120 GS/s
  • 768 Mpts/Ch Analysis Memory
20 GHz/4ch Model
Four channel performance at 20 GHz is pristine with exceptional rise time, overshoot, total and random jitter noise floor, and electrical noise performance.
LeCroy — The Analysis Memory Leader
LeCroy has found a way to make long acquisition memory seamless and pain free to use. The WaveMaster 8 Zi-A Series' proprietary X-Stream II architecture supports capturing, zooming, measuring and analyzing multiple waveforms at up to 768 Mpts deep. WaveMaster 8 Zi-A's proprietary architecture design is augmented with an Intel® Core™ 2 Quad processor (12 GHz effective clock rate), high-speed serial data buses, Windows 7 64-bit OS and 8 GB of RAM. What you experience is processing speed 10-100x faster compared to other oscilloscopes in this class.
Highest Stability Timebase and Lowest Jitter Noise Floor
An exceptionally accurate and stable time base is incorporated for the best possible jitter measurement accuracy jitter noise floor is as low as 125 fsrms. LeCroy provides highly stable measurements at full (768 Mpts) record lengths, simplifying debug of low frequency events.
Freedom from Probing Limitations
High bandwidth differential probes (up to 25 GHz), single-ended active probes, current probes, high-voltage, and mixed signals all connect to the WaveMaster 8 Zi-A oscilloscope and give you a total system view. All WaveMaster 8 Zi-A oscilloscopes contain selectable 50 Ohm and 1 MOhm input capability and can be used with any LeCroy probe - passive or active - without requiring external adapters or power supplies.
Share this article :
 
Support : About Us | Gallery | Contact Us
Copyright © 2016. KALIBONDO - All Rights Reserved
Template Created by Website Published by RT Shop
Proudly powered by Blogger